March 13, 2018

Worker killed in skylight fall

n February 2018, a worker was killed after falling five metres onto a concrete floor. Early investigations indicate the worker was attending to a radio tower on the roof of a storage shed when a skylight has collapsed and he fell through to the floor below. Investigations are continuing.

Preventing a similar incident

This incident highlights the risk of working on or near fragile roof surfaces. Roofs are likely to be fragile if they are made with:

  • asbestos roofing sheets
  • polycarbonate or plastic commonly used in skylights
  • roof lights, particularly those in the roof plane that can be difficult to see in certain light conditions or when hidden by paint
  • fibre cement sheets
  • liner panels on built-up sheeted roofs
  • metal sheets and fasteners where corroded
  • glass, including wired glass
  • chipboard or similar material where rotted
  • wood slabs, slates and tiles.

Processes must be in place to identify all fragile materials before any roof work commences. Protection must be provided if there is a risk of falling through the roof and work is being done on the top of the roof. Control measures to prevent injury from work on fragile roofs are similar to methods used for roof work more generally, including using:

  • an elevating work platform so workers can avoid standing on the roof itself
  • barriers such as guard rails or covers that are secured and labelled with a warning
  • guard rails fitted to all work and access staging or platforms
  • walkways or crawl boards of a suitable size and strength
  • staging on the roof surface to spread the loads
  • safety mesh secured under fragile roofing or skylights. If safety mesh is used, ensure it:
    • conforms to AS/NZS 4389:2015 Roof safety mesh
    • is installed by a competent person in a safe manner and in accordance with the manufacturer’s instructions
    • has its integrity inspected by a competent person prior to roof maintenance or removal
    • is covered by the roof cladding as soon as reasonably practicable after it has been installed
  • a harness system with adequate anchorage points, along with appropriate training and supervision. Wearing harnesses creates a trip hazard, so workers must take extra care with them. Training should include how to rescue someone who falls while using a fall arrest system
  • permanent warning signs at every likely access point to the roof warning of the presence of fragile roofing materials.

Read the full article here.

More news

Project
May 5, 2026

Permanent Access Platform for Hilton Surfers Paradise

There’s a particular challenge that comes with working at height in a premium hotel environment. The solution has to work, every single time, for years to come, and it can’t look like an afterthought bolted onto a building that guests pay quite a large amount to stay in. When fire damage compromised the rope… Read More

Project
March 24, 2026

Safe Roof Access System for Noosa Heads Ambulance Station

At Queensland’s Noosa Heads Ambulance Station, QBuild-Public Works hired RISSafety to design and implement a permanent safety system for their roof. The building required a suitable roof access solution to safely access the roof and service areas, without disturbing the station’s regular emergency operations. Since there was no roof access… Read More

Project
February 23, 2026

Compliant roof safety system for Nowergup Depot

The upgrade of Nowergup Depot’s Railcar Modification Shed was finished in late 2025; a project that increased maintenance capacity for Transperth services in Perth’s north. When DT Infrastructure reached the final stage of this upgrade they engaged RISSafety to design and install a roof safety system. The system would… Read More